The following information may have errors; It is not permissible to be read by anyone who has ever met a lawyer. Use is confined to Engineers with more than 370 course hours of electronic engineering for theoretical studies.
All content entered becomes and is (C)2007 Transtronics, Inc. the property of Transtronics, Inc. Rest assured that your contributions won't be sold and will be publicly available.
ph +1(785) 841 3089 Email inform@xtronics
ProtectArt 2000
From Transwiki
Contents |
[edit] ProtectArt 2000
The ProtectArt 2000 is intended as a museum case temperature and humidity Alarm, monitor and logger. If the case deviates from the programmable limits, the Protect-Art system will indicate an alarm condition via an externally mountable LED. ProtectArt 2000 safeguards priceless collections and provides an accounting trail for curators and insurance companies.
[edit] Applications
While the ProtectArt 2000 was designed for use by museums, many other applications exist where humidity and temperature needs to be monitored and creating a recorded log is advantageous.
- Cigar humidors
- Precision equipment storage
- Greenhouse - Mushroom -
- Incubators
- Research Environmental Chambers
- Condensation control
- Sausage storage
- Musical instruments, violins, guitars
[edit] Basic Operation
Plugging Protect-Art into your computer, allows one to set low and high trip points for temperature and humidity along with other settings. Once alarm points are set up, the external LED will light and blink if the safe range is exceeded. A magnetic sensor allows initiation of a self test without opening the display case.
Protect-Art also logs temperature and humidity allowing one to create graphs to spot long term trends and to prove environmental quality is maintained during transport and inter museum loans.
[edit] Specifications
| Sensor: Humidity | |
|---|---|
| Accuracy (not including non-linearity) |
|
| Non-linearity | less than ±1% RH with software compensation |
| Hysteresis | ±1.0% RH typical |
| Resolution | 0.03% RH (12 bit) |
| Repeatability | ±0.1% RH typical |
| Response Time | 1/4 seconds typical in slowly moving air at 25°C |
| Stability | 1% RH/yr typical |
| Sensor: Temperature | |
| Resolution | 0.01° C (14 bit) |
| Accuracy |
|
| Logging | |
| Storage capacity (Samples) | 2047(RH/Temp pairs) (arrangements for larger storage capacity can be made) |
| Wrap around storage | If the memory is full the unit throws away the oldest value to make room for the newest |
| Sample Interval? | Programmable |
| logged Humidity Resolution | 0.01% |
| logged Temperature Resolution | 0.01°C |
| Time base | +/- 20ppm logged from internal clock (approximately 5 minutes over 3 months) |
| Calibration data to be stored on sensor PCB ??? | |
| Alarms | |
| Types |
|
| Controls | |
| Magnetic test switch | For activating self test without opening case (hold a magnet near by.) When activated, causes remote indicator LED to light solid (not blinking) if no alarm conditions are present. If alarm condition is present, indicator LED will be blinking, indicating an alarm condition. Normally mounted inside display case. |
| Indicators | |
| External Alarm LED | Remotely mounted LED blinks during alarm conditions. connected via included 3.5 mm phone style connector. This output can be configured as an alarm contact - inquire for details. |
| System Status LED | Tri-color LED used during firmware updates ?? |
| Connections | |
| Sensor | 3.5 mm phone jack - a small and easily hidden single sensor for both humidity and temperature |
| Self Test switch | magnetic test-switch via 3.5 mm phone jack cable - operates though glass or wood case wall. |
| Remote LED | 3.5 mm phone |
| Computer Interface | DB9 RS232 serial via 5’ DB9 to DB9 |
| Auxiliary power | ??? |
| Physical | |
| Case Size | 70mm [2.75”] x 125mm[4.94”] x 32.5mm[1.28”] |
| Weight | 230g [0.5lb] |
| Environmental | 10–30°C [50 - 86°F] 5 – 95% RH (non condensing)Operating Temperature Range
|
| Shock | 10G |
| Case | ABS plastic |
| Power Supply | |
| 9V battery |
|
| Battery change time | At least 2 minutes to replace battery without loosing configuration information or logged data. |
| Wall adapter (optional) | ??? for used not limited by battery life. (use with battery for lien failure?) |