[edit] Configuring Meter
Connect both Pins 2 and 3 to 4(common).
Press and hold the front button until a Function number appears. Press the front button repeatably until the function number just before the one you want displays. Now press and hold as the pressing will increment the number and holding will set the meter to the displayed function. (This requires that you plan ahead; just before the function number you want remember you need to press reset, which will increment the function to the one you want but don't let go until the display clears).
The functions are broken up into 3 groups: Timer, Event counter, Frequency/rate
[edit] Timer Functions
In the following table D stands for Days, H - hours, M minutes, and T seconds. There is either a period seperating the time unit fields (allows larger numbers or a dash (easier to read). To the right of the display is a column of the letters DHMT corresponding to the units in the display fields.
| Function Numbers | ||
|---|---|---|
| Timer setups
(Function Numbers 101 - 115) | ||
| Function Number | Display fields | Max display |
| 101 | D.H.M.T | 99.23.59.59 |
| 102 | D.H.M | 9999.23.59 |
| 103 | D-H-M | 99-23-59 |
| 104 | D.H | 999999.23 |
| 105 | D-H | 99999-23 |
| 106 | D | 99999999 |
| 107 | H.M.T | 9999.59.59 |
| 108 | H-M-S | 23-59-59 |
| 109 | H.M | 999999.59 |
| 110 | H-M | 99999-59 |
| 111 | H | 99999999 |
| 112 | M.T | 999999.59 |
| 113 | M-T | 99999-59 |
| 114 | M | 999999999 |
| 115 | T | 999999999 |
| Event Counters (Function numbers 201-206)
(Max is 99,999,999) | ||
|---|---|---|
| Function Number | Edge counted | Max count rate
per roll-off filter |
| 201 | Rising ↑ | 50hz |
| 202 | Falling ↓ | 50hz |
| 203 | Rising ↑ | 100hz |
| 204 | Falling ↓ | 100hz |
| 205 | Rising ↑ | 600hz |
|
|}